
			<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
			<channel>
			<atom:link href="https://www.instecindia.co.in/products.rss" rel="self" type="application/rss+xml" />
			<title>Latest Products</title>
			<link>https://www.instecindia.co.in</link>
			<description>Latest Products</description>
			<lastBuildDate>Fri, 10 Jul 2026 00:32:11 +0530</lastBuildDate>
			<language>en-us</language>
			<generator>https://www.instecindia.co.in</generator>
				<item>
				<title>Door Interlock System</title>
				<link>https://www.instecindia.co.in/door-interlock-system.htm</link>
				<guid>https://www.instecindia.co.in/door-interlock-system.htm</guid>
				<pubDate>Fri, 21 Apr 2023 00:00:00 +0530</pubDate>
				<description>Door Inter Locking System achieves in prevention of process area contamination by in clean room areas &amp;amp; microbiological labs, any personnel passing through an unclassified area to a classified area is required to pass through series of rooms. In each room certain steps need to be followed by defined guidelines prepared by various agencies around the world. This procedure ensures thatthe person is not carrying any external microbiological and particles contamination in to the process area and also the pressure in each room is maintained before openingof door. Door Inter LockingSystem Ensuresthatwhen one doorfora room is - OPEN then all other doors in that particular room are closed. - In Emergency an override key is available on a push button moduleforall door'sopening. - Preventingsimultaneous access of doors/Rooms.&amp;nbsp; &amp;nbsp; Features: Advanced Micro controller based. Supports Maximum number of doors with the cascading of 2 Door and 3 Door. Controlling systems as per user requirements. Support more than 99 Doors in cascading. Supports Emergency &amp;amp; fire alarm Stations. Sequence of door inter Locking is field configurable with the DIP SWITCH. Delay between door openings 10 Sec. Auto close time is 10 Sec. Facility available to read feed back from Magnetic Lock.&amp;nbsp; Easy to installation &amp;amp; userfriendly wiring. Softtouch Membrane keypad. System can also be connect to Building Management System (BMS). &amp;nbsp; OPTIONAL FEATURES Supports Access control module interface. Available Doors Real Time Event Logging and output to PC Connectivity.&amp;nbsp; &amp;nbsp; Door Access Panel Inputs &amp;amp; Outputs&amp;nbsp; Inputs :2 No, switches. per door.&amp;nbsp; Outputs : 2nos. led indicator per switch.&amp;nbsp; &amp;nbsp; Control Card Digital Inputs &amp;amp; Outputs&amp;nbsp; Inputs : 1No, per door.&amp;nbsp; Outputs: 1 relay output230V/ 5A.&amp;nbsp;</description>
				</item>
				<item>
				<title>Air Shower Controller</title>
				<link>https://www.instecindia.co.in/air-shower-controller.htm</link>
				<guid>https://www.instecindia.co.in/air-shower-controller.htm</guid>
				<pubDate>Fri, 21 Apr 2023 00:00:00 +0530</pubDate>
				<description>The Air Shower Controller is a supporting device for the clean workshops &amp;amp; the assembly clean room , is use to blow the dusts attached to the surface of the people &amp;amp; objects entering the clean work shop, &amp;amp; also functions as an air brake to prevent non purified air from entering the clean area. The Air Shower Controller Systems the sequential locking &amp;amp; release of the doors, &amp;amp; controls the blower. The two door are interlocked such that doors cannot be open at the same time, to prevent pressure losses &amp;amp; cross contamination. INSTEC INDIA Air Shower interlocking systems achieve this by preventing simultaneous access of door, also havingset able showertime &amp;amp; manyfeatures.&amp;nbsp; &amp;nbsp; Features: Advanced Micro controller based.&amp;nbsp; Easy to installation &amp;amp; user friendly wiring. Supports Emergency &amp;amp; fire alarm Stations. Softtouch Membrane keypad. Door status indication with LED as well as LCD Display. System can also be connect to Building Management. Delay between door openings 10 Sec System (BMS). Auto close time is 10 Sec. Air Shower Controller. Facility available to read feed back from Magnetic Read Sensors. Timer facility for shower(Blower on time). Supports entryfrom Exitdoors. &amp;nbsp; OPTIONAL FEATURES Supports Access control module interface. Available Doors Real Time Event Logging and output to PC Connectivity.&amp;nbsp; &amp;nbsp; DoorAccess Panel Inputs &amp;amp; Outputs&amp;nbsp; Inputs : 2 Nos. switches per door.&amp;nbsp; Outputs :2Nos. led indicator per switch.&amp;nbsp; &amp;nbsp; Control Card Digital Inputs &amp;amp; Outputs&amp;nbsp; Inputs : 1Nos. per door.&amp;nbsp; Outputs : 4Nos. relay output 230V/ 5 A.&amp;nbsp; &amp;nbsp; Keys &amp;amp; Programming&amp;nbsp; 4 Soft touch Programming keys&amp;nbsp; Programmable Delay between each door 0 to 99 Sec.&amp;nbsp; Programmable various Timer for controlling action.&amp;nbsp; Non-Volatile Flash Memory.&amp;nbsp;</description>
				</item>
				<item>
				<title>Static and Dynamic Pass Box Controller</title>
				<link>https://www.instecindia.co.in/static-and-dynamic-pass-box-controller.htm</link>
				<guid>https://www.instecindia.co.in/static-and-dynamic-pass-box-controller.htm</guid>
				<pubDate>Wed, 26 Apr 2023 00:00:00 +0530</pubDate>
				<description>The Static/Dynamic Pass Box inter locking system controls the sequential locking and release of the doors and control the blower, U.V. Tube &amp;amp; CFTube also. The opening/closing of the door is manual or ideally through a closure mechanism. In normal condition, both the doors should be in locked state. any door can open by pressing switch of keypad shows the status of operation. Various visual/ audio indications indicates status of operations or any problem occurs in the operations. Pass box is used for material transfer from one Clean room or unclassified area to anotherclean room or classified area. It consists of a rectangular box with two doors/three doors. The all doors are interlocked such that all doors cannot be open at the same time, to prevent pressure losses and cross contamination at the time of the material transferring process. Preventing simultaneous access of doors/Rooms.&amp;nbsp; &amp;nbsp; Features: Advance Micro controller base technology. Support upto 3 doors. &amp;amp; Double door option available. Doorstatus indication with LED as well as LCD display. Auto controlling facility of U.V. LIGHT, CF LIGHT &amp;amp; BLOWER as well as manually ON/OFF. Inbuilt U.V. HOUR METER . Password facility. Support Electro Magnetic Lock/Electric Strikers. Support Emergency &amp;amp; Fire Stations. Easyto installation &amp;amp; userfriendly Support RS485.&amp;nbsp; &amp;nbsp; Timer for&amp;nbsp; Door Opening Time.&amp;nbsp; Door ClosingTime. Blower On Time. U.V. On Time. Process Timer. BuzzerTimer. &amp;nbsp; DoorAccess Panel Inputs &amp;amp; Outputs&amp;nbsp; Inputs : 2 Nos. switches perdoor. Outputs: 2Nos. led indicator perswitch. &amp;nbsp; Control Card Digital Inputs &amp;amp; Outputs Inputs : 1Nos. perdoor. Outputs: 5Nos. relay output. &amp;nbsp; Keys &amp;amp; Programming 4 Softtouch Programming keys. Programmable Delay between each door 0 to 99 Sec. Programmable various Timer for controlling action.&amp;nbsp; Non-Volatile Flash Memory.</description>
				</item>
				<item>
				<title>Temperature Humidity and Pressure Monitor</title>
				<link>https://www.instecindia.co.in/temperature-humidity-and-pressure-monitor.htm</link>
				<guid>https://www.instecindia.co.in/temperature-humidity-and-pressure-monitor.htm</guid>
				<pubDate>Fri, 21 Apr 2023 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Flameproof Door Interlock System</title>
				<link>https://www.instecindia.co.in/flameproof-door-interlock-system.htm</link>
				<guid>https://www.instecindia.co.in/flameproof-door-interlock-system.htm</guid>
				<pubDate>Fri, 21 Apr 2023 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Flameproof Pass Box Interlocking system</title>
				<link>https://www.instecindia.co.in/flameproof-pass-box-interlocking-system.htm</link>
				<guid>https://www.instecindia.co.in/flameproof-pass-box-interlocking-system.htm</guid>
				<pubDate>Wed, 26 Apr 2023 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Flameproof Passbox Control System</title>
				<link>https://www.instecindia.co.in/flameproof-passbox-control-system.htm</link>
				<guid>https://www.instecindia.co.in/flameproof-passbox-control-system.htm</guid>
				<pubDate>Fri, 21 Apr 2023 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Flameproof UV Tube Light</title>
				<link>https://www.instecindia.co.in/flameproof-uv-tube-light.htm</link>
				<guid>https://www.instecindia.co.in/flameproof-uv-tube-light.htm</guid>
				<pubDate>Fri, 21 Apr 2023 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Electromagnetic Door Locks</title>
				<link>https://www.instecindia.co.in/electromagnetic-door-locks.htm</link>
				<guid>https://www.instecindia.co.in/electromagnetic-door-locks.htm</guid>
				<pubDate>Mon, 24 Apr 2023 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Laminar Airflow Controller with Dpg</title>
				<link>https://www.instecindia.co.in/laminar-airflow-controller-with-dpg.htm</link>
				<guid>https://www.instecindia.co.in/laminar-airflow-controller-with-dpg.htm</guid>
				<pubDate>Wed, 26 Apr 2023 00:00:00 +0530</pubDate>
				<description></description>
				</item>
			</channel>
			</rss>